Á¦Ç° ¼Ò°³ > HPLC°ü·ÃÁ¦Ç° > Fraction Collector > ISCO |
|
|
 |
 |
| |
| |
Isco Foxy¢ç Junior Fraction Collectors |
ÀÚ¼¼ÇÑ ³»¿ëÀ» º¸½Ã·Á¸é PDFÆÄÀÏ ´Ù¿î·Îµå¹öưÀ» ´©¸£¼¼¿ä
|
 |
Sturdy cast aluminum frame |
Easy to use symbolic touch screen
interface |
Built-in Ethernet and RS-232
communication capabilities |
Faster tube changes |
¥ìL delay volume between diverter
valve and drop former |
25 mL/minute standard flow rate,
options up to 1,000 mL/minute |
|
|
|
The two-rack Foxy R2 fraction collector uses
radio frequency identification to automatically
detect collection racks for easy setup.
These cold room compatible fraction collectors
can be adapted to a broad spectrum of
applications. The units can distribute fractions
into 96 well microplates, standard tube
sizes, and bottles. For essentially unlimited
volumes, funnel racks can direct fluids to any
collection vessel or downstream process.
Multiple fraction collectors may be "daisy
chained" together to increase your fraction
capacity - an exclusive feature from
Teledyne Isco. |
|
| |
|
| Size |
Foxy R1: 12.25, 13.0, 14.0 inches (31.1, 33.0, 35.5 cm)
Foxy R2: 12.25, 21.0, 14.9 inches (31.1, 53.3, 37.8 cm) |
| Weigh |
Foxy R1: 16.95 lbs (7.7 kg)
Foxy R2: 23.4 lbs (10.6 kg)
(with drip tray, no rack) |
| Maximum flow rate |
25 mL/min standard, optional 150 mL/min kit,
(Foxy R2 only) optional 1,000 mL/min valve |
| Delay volume |
Diverter valve located at drop former.
Delay volume compensation only required for
length of tubing to the diverter valve. |
| Peak detection |
Slope and/or level sense,
with or without time window |
| Tube changes |
At detected peaks, plus drop counts, time,
or external pump counts. |
| System control |
Operator: front-panel control via touch-screen LCD
Integrated systems: direct communication with
fraction collector via Ethernet (TCP/IP) and
RS-232 serial communications. |
| Inputs |
Pump counter1, external peak1, inject1,
tube advance1, analog peak voltage2. |
| Outputs |
Pump pause3, tube change3. |
| Operating voltages |
100/117 VAC 50/60 Hz, 234 VAC 50/60 Hz |
| |
Notes:
1. High on +3.3 to 5 V or contact closure, active low, 30 ms min, 5 VDC max.
2. 0 to 1.0 V nominal, -1.2 to +1.2 V usable, -5 to +5 V max.
3. Outputs are open collector active low, 30 ms min, 5 VDC max. |
|
| |
|
| Isco Foxy Fraction Collector Ordering Information |
| Cat. No. |
Description |
FC-R1
|
Foxy R1, Single rack collector |
| FC-R2 |
Foxy R2, 2 rack collector, w/rack sensing |
| Connection Cables for Foxy R1 and R2 |
| Cat. No. |
Description |
| FCC-474 |
Remote start signal from HP1100/1200 and peak separation
|
| FCC-170 |
Pump cable connection (any pump) |
| FCC-171 |
Detector cable connection (contact closure
or TTL I/O) |
| Optional Racks for FC-R2 Only, Each: |
| Cat. No. |
Description |
| FCR-155 |
(144) 12mm dia. tubes |
| FCR-150 |
(144) 13mm dia. tubes |
| FCR-154 |
(60) 1.5mL microcentrifuge tubes |
| FCR-151 |
(100) 16mm dia. tubes |
| FCR-152 |
(72) 18mm dia. tubes |
| FCR-158 |
(72) MiniVials |
| FCR-156 |
(36) 28mm dia. scintillation vials |
| FCR-153 |
(36) 25mm dia. tubes |
| FCR-157 |
(36) 50mL cone-bottom centrifuge tubes, 28-29mm diameter x 150mm |
| FCR-159 |
(2) 96-well microplates |
| Optional Racks for FC-R1 and FC-R2, Each: |
| Cat. No. |
Description |
| FCR-161 |
Preparative rack with (26) Halar funnels for large fractions (requires qty 1)
|
| FCR-162 |
Preparative rack with (26) Halar funnels for large fractions (requires qty 1).
Organic compatible |
|
|
|
|
| |
|