home sitemap sitemap
ÈÞÅØ½º
·Î±×ÀÎ
  ¾ÆÀ̵ð ÀúÀå
Á¦Ç°¼Ò°³
ÈÞÅØ½º Á¦Ç°
HPLC System
HPLC Autosampler
HPLC Column Oven
Solvent Delivery System
GPC system
HPLC °ü·ÃÁ¦Ç°
Autosampler
Column
Column Heater
Data Management Software
Degasser
Detector
Fraction Collector
GC Accessaries
HPLC Accessaries
HPLC System
Pickering
 Pump
Sample Prepreption
Standards
 
Á¦Ç°¼Ò°³
À§Ä¡ Á¦Ç° ¼Ò°³ > HPLC°ü·ÃÁ¦Ç° > Fraction Collector > ISCO
HPLC°ü·Ã Á¦Ç°
Fraction Collector
  ISCO  
 
Isco Foxy¢ç Junior Fraction Collectors
ÀÚ¼¼ÇÑ ³»¿ëÀ» º¸½Ã·Á¸é PDFÆÄÀÏ ´Ù¿î·Îµå¹öưÀ» ´©¸£¼¼¿ä PDFÆÄÀÏ ´Ù¿î·Îµå
Á¦Ç°¼³¸í
Sturdy cast aluminum frame
Easy to use symbolic touch screen interface
Built-in Ethernet and RS-232 communication capabilities
Faster tube changes
¥ìL delay volume between diverter valve and drop former
25 mL/minute standard flow rate, options up to 1,000 mL/minute
The two-rack Foxy R2 fraction collector uses radio frequency identification to automatically detect collection racks for easy setup. These cold room compatible fraction collectors can be adapted to a broad spectrum of
applications. The units can distribute fractions into 96 well microplates, standard tube sizes, and bottles. For essentially unlimited volumes, funnel racks can direct fluids to any collection vessel or downstream process.
Multiple fraction collectors may be "daisy chained" together to increase your fraction capacity - an exclusive feature from Teledyne Isco.
 
Á¦Ç°¼³¸í
Size Foxy R1: 12.25, 13.0, 14.0 inches (31.1, 33.0, 35.5 cm)
Foxy R2: 12.25, 21.0, 14.9 inches (31.1, 53.3, 37.8 cm)
Weigh Foxy R1: 16.95 lbs (7.7 kg)
Foxy R2: 23.4 lbs (10.6 kg)
(with drip tray, no rack)
Maximum flow rate 25 mL/min standard, optional 150 mL/min kit, (Foxy R2 only) optional 1,000 mL/min valve
Delay volume Diverter valve located at drop former.
Delay volume compensation only required for length of tubing to the diverter valve.
Peak detection Slope and/or level sense,
with or without time window
Tube changes At detected peaks, plus drop counts, time, or external pump counts.
System control Operator: front-panel control via touch-screen LCD
Integrated systems: direct communication with fraction collector via Ethernet (TCP/IP) and RS-232 serial communications.
Inputs Pump counter1, external peak1, inject1, tube advance1, analog peak voltage2.
Outputs Pump pause3, tube change3.
Operating voltages 100/117 VAC 50/60 Hz, 234 VAC 50/60 Hz
 
Notes:
1. High on +3.3 to 5 V or contact closure, active low, 30 ms min, 5 VDC max.
2. 0 to 1.0 V nominal, -1.2 to +1.2 V usable, -5 to +5 V max.
3. Outputs are open collector active low, 30 ms min, 5 VDC max.
 
Á¦Ç°¼³¸í
Isco Foxy Fraction Collector Ordering Information
Cat. No. Description
FC-R1
Foxy R1, Single rack collector
FC-R2 Foxy R2, 2 rack collector, w/rack sensing

Connection Cables for Foxy R1 and R2
Cat. No. Description
FCC-474 Remote start signal from HP1100/1200 and peak separation
FCC-170 Pump cable connection (any pump)
FCC-171 Detector cable connection (contact closure or TTL I/O)

Optional Racks for FC-R2 Only, Each:
Cat. No. Description
FCR-155 (144) 12mm dia. tubes
FCR-150 (144) 13mm dia. tubes
FCR-154 (60) 1.5mL microcentrifuge tubes
FCR-151 (100) 16mm dia. tubes
FCR-152 (72) 18mm dia. tubes
FCR-158 (72) MiniVials
FCR-156 (36) 28mm dia. scintillation vials
FCR-153 (36) 25mm dia. tubes
FCR-157 (36) 50mL cone-bottom centrifuge tubes, 28-29mm diameter x 150mm
FCR-159 (2) 96-well microplates

Optional Racks for FC-R1 and FC-R2, Each:
Cat. No. Description
FCR-161 Preparative rack with (26) Halar funnels for large fractions (requires qty 1)
FCR-162 Preparative rack with (26) Halar funnels for large fractions (requires qty 1).
Organic compatible
 
Quick Menu
¹¯°í´äÇϱâ
¼¼¹Ì³ª¾È³»
°ü·Ã±â°ü
top